BS-2081F Trinocular Research Fluorescent Biological Microscope

BestScope continues to explore the research needs of specialized fields such as pathology, cytology and virology, and continuously optimizes and upgrades the BS-2081 series of scientific grade upright microscopes to have near-perfect optical performance and mechanical structure design. NIS Infinity Optical System has precise imaging and chromatic aberration correction capabilities. The illumination system with high color reproduction, high-quality optics and full-featured accessories makes these microscopes ideal for cutting-edge life science research where darkfield of view, differential interference contrast or high-performance fluorescence are required. In addition, a wide range of motorized and intelligent components and powerful imaging software meet the needs of quick sample overview and detailed sample inspection, making repetitive tasks easy and greatly increasing ease and comfort for maximum productivity. No matter in a clinical laboratory or a research laboratory, the BS-2081 series microscopes provide the ideal microscopy imaging solution.


Product Detail

Download

Quality Control

Product Tags

BS-2081F Research Fluorescent Biological Microscope

BS-2081F

Introduction

BestScope continues to explore the research needs of specialized fields such as pathology, cytology and virology, and continuously optimizes and upgrades the BS-2081 series of scientific grade upright microscopes to have near-perfect optical performance and mechanical structure design. NIS Infinity Optical System has precise imaging and chromatic aberration correction capabilities. The illumination system with high color reproduction, high-quality optics and full-featured accessories makes these microscopes ideal for cutting-edge life science research where darkfield of view, differential interference contrast or high-performance fluorescence are required. In addition, a wide range of motorized and intelligent components and powerful imaging software meet the needs of quick sample overview and detailed sample inspection, making repetitive tasks easy and greatly increasing ease and comfort for maximum productivity. No matter in a clinical laboratory or a research laboratory, the BS-2081 series microscopes provide the ideal microscopy imaging solution.

Feature

20811

Sapphire Glass Stage is optional.

Mechanical stage with sapphire glass insert is optional, it is endurable, never could be scratched and allows users to clear the stage easily.

Put Slide by One Hand.  

It is easy for users to put slides by one hand due to the special designed slide clip.

20812
20813

Tilting Trinocular Head is optional.

(1) The eye tube can be adjusted from 0°-35°.
(2) Digital cameras or DSLR cameras can be connected to the trinocular tube.
(3) The beam splitter has 3-position (100:0, 20:80, 0:100).
The splitter bar can be assembled on the either side according to user’s requirements.

ECO Function

The transmitted light would be off automatically after 30 minutes from operators leave. It can not only save energy, but also keep the lamp life longer.

20814
20815

Low Position X-Y Knobs.

The height of the stage control knobs can be adjusted up or down by 18mm to ensure a comfortable hand position, the tension of X-Y control knob also can be adjusted.

BS-2081L has Intelligent operating system.
(1) Coded Nosepiece with light intensity memory function.
The BS-2081L microscope can memorize the illumination brightness when using each objective. When the objective has been changed, the light intensity will be automatically adjusted to reduce visual fatigue and improve work efficiency.

BS-2081 switching magnifications of Sample picture

(2) Use a dimming knob to achieve multiple functions.

One Click: Enter standby status

Double Clicks: Light lock or unlock

Rotation: Adjust brightness

Press + Up-spin: Switch to the upper light source

Press + Down-spin: Switch to the under light source

Press 3 seconds: Set the time of turning off the light after leaving.

20815

(3) The display of microscope working status.
The LCD on the front of the microscope can display the working status of the microscope, including magnification, light intensity, sleepy model and so on.

BS-2081 display the working status

(4) Color temperature adjustment function.
The color temperature can be adjusted from yellow to white, which can lead to a better contrast and meet the requirements of various research.

Application

BS-2081 series research microscopes are ideal instrument in biological, histological, pathological, bacteriology, immunizations and pharmacy field and can be widely used in medical and sanitary establishments, laboratories, institutes, academic laboratories, colleges and universities.

Specification

Item

Specification

BS-2081

BS-2081L

BS-2081F

BS-2081F (LED)

Optical System NIS60 Infinite Color Corrected Optical System

Viewing Head Seidentopf Trinocular Head, 30° inclined, interpupillary distance: 47mm-78mm; splitting ratio Eyepiece: Trinocular=100:0 or 20:80 or 0:100

Ergo Tilting Trinocular Head, adjustable 0-35° inclined, interpupillary distance 47mm-78mm; splitting ratio Eyepiece: Trinocular=100:0 or 20:80 or 0:100

Seidentopf Binocular Head, 30° inclined, interpupillary distance: 47mm-78mm

Eyepiece Super wide field plan eyepiece SW10X/25mm, diopter adjustable

Super wide field plan eyepiece SW10X/22mm, diopter adjustable

Extra wide field plan eyepiece EW12.5X/17.5mm, diopter adjustable

Wide field plan eyepiece WF15X/16mm, diopter adjustable

Wide field plan eyepiece WF20X/12mm, diopter adjustable

Objective N-PLN Plan Objective N-PLN 2X/NA=0.06, WD=7.5mm

N-PLN 4X/NA=0.10, WD=30mm

N-PLN 10X/NA=0.25, WD=10.2mm

N-PLN 20X/NA=0.40, WD=12mm

N-PLN 40X/NA=0.65, WD=0.7mm

N-PLN 100X(Oil)/NA=1.25, WD=0.2mm

N-PLN 50X(Oil)/NA=0.95, WD=0.19mm

N-PLN 60X/NA=0.80, WD=0.3mm

N-PLN-I 100X (Oil, with Iris Diaphragm)/ NA=0.5-1.25, WD=0.2mm

N-PLN PH Plan Phase Contrast Objective N-PLN PH 10X/NA=0.25, WD=10.2mm

N-PLN PH 20X/NA=0.40, WD=12mm

N-PLN PH 40X/NA=0.65, WD=0.7mm

N-PLN PH 100X(Oil)/NA=1.25, WD=0.2mm

N-PLFN Plan Semi-apochromatic Fluorescent Objective N-PLFN 4X/NA=0.13, WD=17.2mm

N-PLFN 10X/NA=0.30, WD=16.0mm

N-PLFN 20X/NA=0.50, WD=2.1mm

N-PLFN 40X/NA=0.75, WD=1.5mm

N-PLFN 100X(Oil)/NA=1.4, WD=0.16mm

N-PLFN PH Plan Semi-apochromatic Fluorescent Phase Contrast Objective N-PLFN PH 10X/NA=0.30, WD=15.8mm

N-PLFN PH 20X/NA=0.50, WD=2.7mm

N-PLFN PH 40X/NA=0.75, WD=1.35mm

N-PLFN PH 100X(Oil)/NA=1.40, WD=0.18mm

N-PLPN Plan Apochromatic Objective N-PLPN 10X/NA=0.45, WD=4.0mm

N-PLPN 20X/NA=0.75, WD=1.1mm

N-PLPN 40X/NA=0.95, WD=0.21mm

N-PLPN 60X(Oil)/NA=1.42, WD=0.25mm

N-PLPN 100X(Oil)/NA=1.45, WD=0.13mm

Nosepiece Backward Sextuple Nosepiece (with DIC slot)

Backward Coded Sextuple Nosepiece (with DIC slot)

Condenser Swing-out type condenser N.A.0.9/0.25

Turret Phase Contrast Condenser

Dark-field Condenser (Dry), used for objectives lower than 100X

Dark-field Condenser (Oil), used for 100X objective

Transmitted Illumination 3W S-LED lamp, center pre-set, intensity adjustable

3W S-LED lamp, center pre-set, intensity adjustable. LCD screen with illumination management system

12V/100W halogen lamp, center pre-set, intensity adjustable

Focusing Low-position coaxial coarse and fine focusing, fine division 1μm, Moving range 35mm

Stage Double layers mechanical stage, size 190mmX152mm; moving range 78mmX54mm (double slide holder, Right or left handle); precision: 0.1mm, with Ultra-hard Glass Insert

Double layers mechanical stage, size 190mmX152mm; moving range 78mmX54mm (double slide holder, Right or left handle); precision: 0.1mm; with Sapphire Crystal Glass Insert

DIC Kit Polarizer for DIC Kit

DIC insert plate(10X/20X), can be inserted into the DIC slot on nosepiece

DIC insert plate(40X/100X) can be inserted into the DIC slot on nosepiece

DIC Turret Condenser (10X, 20X/40X, 100X Warrior Prism inside)

Reflected Fluorescence Illuminator (with mercury lamp) Turret with 6 filter block cubes position, with iris field diaphragm and aperture diaphragm, central adjustable; with filter slot; with fluorescence B, G filters

100W mercury lamp house, filament center and focus adjustable; with reflected mirror, mirror center and focus adjustable.

Digital power controller, wide voltage 100-240VAC

ND6/ND25 Filter

U, V, R, FITC, DAPI, TRITC, Auramine, mCherry, FL-BG fluorescent filters

Reflected Fluorescent Attachment (with LED lamps) LED Reflected Fluorescent Attachment, Turret with 6-position for filter block cubes, including B, G fluorescent filters and B, G, U, R LED lamps (the LED lamps can be used for B, G, U, R, FITC, DAPI, TRITC fluorescent filters), there are 4 positions for the LED lamps

U, R, FITC, DAPI, TRITC fluorescent filters

Filter for Transmitted Illumination Green Filter 45mm

Blue Filter 45mm

Yellow Filter 45mm

Red Filter 45mm

ND6 Filter

ND25 Filter

Other Accessories 0.5X C-mount Adapter

1X C-mount Adapter

Dust Cover

Power Cord

Cedar Oil 5ml

Simple Polarizing kit

Calibration slide 0.01mm

Multi Viewing Attachment for 2/3/5/7/10 person

Note: ● Standard Outfit, ○ Optional

Accessories

BS-2081 Plan Objectives
  1. N-PLN Series Plan Objectives.
  2. The plan objectives can provide flat high transmittance image from visible light to NIR light. They are usually used for bright-field viewing as the high signal-to-noise, high resolution and high contrast features.
BS-2081 Plan Phase Contrast Objectives
  1. N-PLN PH Series Plan Phase Contrast Objectives.
  2. These plan phase contrast objectives are specially designed for phase contrast observation. They are good choice for clinic and scientific research. These objectives can provide advanced flat image of 25mm FOV under transmitted bright field.
BS-2081 Plan Semi-APO Fluorescent Objectives
  1. N-PLFN Series Plan Semi-APO Fluorescent Objectives.
  1. Owe to the multilayers coating technology, these Semi-APO objectives can compensate the spherical aberration and the chromatic aberration from ultraviolet and infrared light. High-sensitive fluorescence performance of the objectives ensures the sharpness, definition and color rendition of images.
BS-2081 Plan Apochromatic Fluorescent Objective

 N-PLPN Plan Apochromatic Fluorescent Objective

The newly developed advanced apochromatic objective lenses have high level of chromatic aberration correction capability and high resolution, ensuring a high level of wave-phase contrast correction with full field of view, these APO objectives are ideal for routine laboratory observation work and digital imaging.

BS-2081 Bright field Viewing

Mammary Gland (active stage)

Bright field Viewing.

Brighter image, high resolution and flatness, suitable for all the magnifications.

BS-2081 Fluorescent Viewing

Arterial Cell

Fluorescent Viewing.

The compact epi-fluorescent components include noise elimination feature which ensures images captured are bright, with high contrast and high signal-to-noise ratio.

BS-2081 epi-fluorescent components
BS-2081 fluorescent components
BS-2081 sample pictures
BS-2081 Fluorescent filters (2)

Excitation

Excitation Filter

Dichroic Mirror

Barrier Filter

LED lamp Wave Length

Application

B

BP460-495

DM505

BA510

485nm

·FITC: Fluorescent antibody method·Acidine orange: DNA, RNA

·Auramine: Tubercle bacillus

·EGFP, S657, RSGFP

G

BP510-550

DM570

BA575

535nm

·Rhodamine, TRITC: Fluorescent antibody method·Propidium iodide: DNA

·RFP

U

BP330-385

DM410

BA420

365nm

·Auto-fluorescence observation·DAPI: DNA staining

·Hoechest 332528, 33342: used for Chromosome staining

V

BP400-410

DM455

BA460

405nm

·Catecholamines·5-hydroxy tryptamine

·Tetracycline: Skeleton, Teeth

R

BP620-650

DM660

BA670-750

640nm

·Cy5·Alexa Fluor 633, Alexa Fluor 647

FITC

BP460-495

DM505

BA510-550

485nm

·FITC: Fluorescent antibody method

DAPI

BP360-390

DM415

BA435-485

365nm

DAPI: DNA staining

TRITC

BP528-553

DM565

BA578-633

535nm

·TRITC: Fluorescent antibody method

FL-Auramine

BP470

DM480

BA485

450nm

·Auramine O, Testing for tuberculosis

Texas Red

BP540-580

DM595

BA600-660

560nm

It is commonly conjugated to antibodies and proteins for cellular imaging applications.

mCherry

BP542-582

DM593

BA605-675

560nm

Molecular labeling and cellular component localization

FL-BG

BP 453-490/533-588

DM 495-548/595-705

BA 500-540/603-664

485nm/525nm

·FITC: Fluorescent antibody method·Acidine orange: DNA, RNA

·Auramine: Tubercle bacillus

·EGFP, S657, RSGFP

·Rhodamine, TRITC: Fluorescent antibody method

·Propidium iodide: DNA

·RFP

Note:

1. All the above fluorescent filters can be used on BS-2081F.
2. Filters Size in fluorescent block: Excitation and Barrier Filters is Φ24.8mmX3.6mm (thickness with metal edge), Dichroic Mirror is 37.5X28.5X1mm, the filters can be installed in the block.

BS-2081 Phase Contrast Viewing

Rat Ovarian Cell

Phase Contrast Viewing.

Users can get high contrast image of neutral background color whatever the magnification is. It is suitable for viewing non-stained specimen.

BS-2081 Polarizing Viewing

Uric Acid Crystal

Polarizing Viewing.

It is quite suitable for viewing collagen, amyloid and crystal etc., double refracting specimens.

BS-2081 Dark-field Viewing

Spirogyra

Dark-field Viewing.

It can be used for clearly viewing of blood or flagellum etc., fine structure.

BS-2081 DIC Attachment
BS-2081 DIC Attachment of sample pictures

DIC Attachment.

The DIC attachment can be used to observe unstained specimens. It including:

1. Semi-APO objective

2. Turret DIC condenser

3. Polarizer

4. DIC Plate

Multi Viewing Heads

BS-2083MH4A (For 2 users, Face to Face)

BS-2083MH4A (For 2 users, Face to Face)

BS-2083MH4B (For 2 users, Side by Side)

BS-2083MH4B (For 2 users, Side by Side)

BS-2083MH6(For 3 users)

BS-2083MH6(For 3 users)

BS-2083MH10(For 5 users)

BS-2083MH10(For 5 users)

BS-2081MH20 (For 10 users)

BS-2081MH20 (For 10 users)

Note: We have not captured images with BS-2081, so we use BS-2083 to illustrate, BS-2081MH series are different with BS-2083 series on main microscope body.

 LED Fluorescent Attachment.

BS-2081 LED Fluorescent Attachment2
BS-2081 LED Fluorescent Attachment2
BS-2081 fluorescent filters

The LED Reflected Fluorescent Attachment has turret with 6-position for filter block cubes, standard configuration including B, G fluorescent filters and B, G, U, R LED lamps, the LED lamps can be used for B, G, U, R, FITC, DAPI, TRITC fluorescent filters (U, R, FITC, DAPI, TRITC fluorescent filters are optional), there are 4 positions for the LED lamps. The fluorescent filters are reliable and precise, which offers high performance for various demands.

Sample Images

20816
BS-2081 Series Sample picture (3)
BS-2081 Series Sample picture (1)
BS-2081 Series Sample picture (4)

System Diagram

BS-2081 System Diagram

Dimension

BS-2081&BS-2081L Dimension

BS-2081&BS-2081L

BS-2081F Dimension

 BS-2081F

Unit: mm

Certificate

mhg

Logistics

pic (3)

  • Previous:
  • Next:

  • BS-2081 Series Research Biological Microscope

    pic (1) pic (2)

  • Write your message here and send it to us